Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
PLoS One ; 16(1): e0245134, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33411747

RESUMO

OBJECTIVES: To assess the feasibility of quantitative analysis of dynamic computed tomography angiography (dCTA) for the detection of endoleaks in patients who underwent endovascular repair of abdominal aortic aneurysms (EVAR). MATERIAL AND METHODS: Twenty patients scheduled for contrast-enhanced CT angiography (CTA) of the abdominal aorta post-EVAR were prospectively enrolled. All patients received a standard triphasic CTA protocol, followed by an additional dCTA. The dCTA acquisition enabled reconstruction of color-coded maps depicting blood perfusion and a dCTA dataset of the aneurysm sac. Observers assessed the dCTA and dynamic CT perfusion (dCTP) images for the detection of endoleaks, establishing diagnostic confidence based on a modified 5-point Likert scale. An index was calculated for the ratio between the endoleak and aneurysm sac using blood flow for dCTP and Hounsfield units (HU) for dCTA. The Wilcoxon test compared the endoleak index and the diagnostic confidence of the observers. RESULTS: In total, 19 patients (18 males, median age 74 years [70.5-75.7]) were included for analysis. Nine endoleaks were detected in 7 patients using triphasic CTA as the reference standard. There was complete agreement for endoleak detection between the two techniques on a per-patient basis. Both dCTA and dCTP identified an additional endoleak in one patient. The diagnostic confidence using dCTP for detection of endoleaks was not significantly superior to dCTA (5.0 [5-5] vs. 4.5 [4-5], respectively; p = 0.11); however, dCTP demonstrated superior diagnostic confidence for endoleak exclusion compared to dCTA (1.0 [1-1] vs 1.5 [1.5-1.5], respectively; p <0.01). Moreover, the dCTP endoleak index was significantly higher than the dCTA index (18.5 [10.8-20.5] vs. 3.5 [5-2.7], respectively; p = 0.02). CONCLUSIONS: Quantitative analysis of dCTP imaging can aid in the detection of endoleaks and demonstrates a higher endoleak detection rate than triphasic CTA, as well as a strong correlation with visual assessment of dCTA images.


Assuntos
Aorta Abdominal , Aneurisma da Aorta Abdominal , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Idoso , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Feminino , Humanos , Masculino
2.
J Thorac Imaging ; 36(6): 345-352, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-32205821

RESUMO

OBJECTIVES: Computed tomography (CT) myocardial perfusion imaging (CT-MPI) with hyperemia induced by regadenoson was evaluated for the detection of myocardial ischemia, safety, relative radiation exposure, and patient experience compared with single-photon emission computed tomography (SPECT) imaging. MATERIALS AND METHODS: Twenty-four patients (66.5 y, 29% male) who had undergone clinically indicated SPECT imaging and provided written informed consent were included in this phase II, IRB-approved, and FDA-approved clinical trial. All patients underwent coronary CT angiography and CT-MPI with hyperemia induced by the intravenous administration of regadenoson (0.4 mg/5 mL). Patient experience and findings on CT-MPI images were compared to SPECT imaging. RESULTS: Patient experience and safety were similar between CT-MPI and SPECT procedures and no serious adverse events due to the administration of regadenoson occurred. SPECT resulted in a higher number of mild adverse events than CT-MPI. Patient radiation exposure was similar during the combined coronary computed tomography angiography and CT-MPI (4.4 [2.7] mSv) and SPECT imaging (5.6 [1.7] mSv) (P-value 0.401) procedures. Using SPECT as the reference standard, CT-MPI analysis showed a sensitivity of 58.3% (95% confidence interval [CI]: 27.7-84.8), a specificity of 100% (95% CI: 73.5-100), and an accuracy of 79.1% (95% CI: 57.9-92.87). Low apparent sensitivity occurred when the SPECT defects were small and highly suspicious for artifacts. CONCLUSIONS: This study demonstrated that CT-MPI is safe, well tolerated, and can be performed with comparable radiation exposure to SPECT. CT-MPI has the benefit of providing both complete anatomic coronary evaluation and assessment of myocardial perfusion.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Angiografia Coronária , Estudos de Viabilidade , Feminino , Humanos , Masculino , Purinas , Pirazóis , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
3.
J Thorac Imaging ; 35 Suppl 1: S49-S57, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32168163

RESUMO

PURPOSE: The purpose of this study was to evaluate the accuracy of a novel fully automated deep learning (DL) algorithm implementing a recurrent neural network (RNN) with long short-term memory (LSTM) for the detection of coronary artery calcium (CAC) from coronary computed tomography angiography (CCTA) data. MATERIALS AND METHODS: Under an IRB waiver and in HIPAA compliance, a total of 194 patients who had undergone CCTA were retrospectively included. Two observers independently evaluated the image quality and recorded the presence of CAC in the right (RCA), the combination of left main and left anterior descending (LM-LAD), and left circumflex (LCx) coronary arteries. Noncontrast CACS scans were allowed to be used in cases of uncertainty. Heart and coronary artery centerline detection and labeling were automatically performed. Presence of CAC was assessed by a RNN-LSTM. The algorithm's overall and per-vessel sensitivity, specificity, and diagnostic accuracy were calculated. RESULTS: CAC was absent in 84 and present in 110 patients. As regards CCTA, the median subjective image quality, signal-to-noise ratio, and contrast-to-noise ratio were 3.0, 13.0, and 11.4. A total of 565 vessels were evaluated. On a per-vessel basis, the algorithm achieved a sensitivity, specificity, and diagnostic accuracy of 93.1% (confidence interval [CI], 84.3%-96.7%), 82.76% (CI, 74.6%-89.4%), and 86.7% (CI, 76.8%-87.9%), respectively, for the RCA, 93.1% (CI, 86.4%-97.7%), 95.5% (CI, 88.77%-98.75%), and 94.2% (CI. 90.2%-94.6%), respectively, for the LM-LAD, and 89.9% (CI, 80.2%-95.8%), 90.0% (CI, 83.2%-94.7%), and 89.9% (CI, 85.0%-94.1%), respectively, for the LCx. The overall sensitivity, specificity, and diagnostic accuracy were 92.1% (CI, 92.1%-95.2%), 88.9% (CI. 84.9%-92.1%), and 90.3% (CI, 88.0%-90.0%), respectively. When accounting for image quality, the algorithm achieved a sensitivity, specificity, and diagnostic accuracy of 76.2%, 87.5%, and 82.2%, respectively, for poor-quality data sets and 93.3%, 89.2% and 90.9%, respectively, when data sets rated adequate or higher were combined. CONCLUSION: The proposed RNN-LSTM demonstrated high diagnostic accuracy for the detection of CAC from CCTA.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Aprendizado Profundo , Redes Neurais de Computação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Inteligência Artificial , Vasos Coronários/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tempo , Calcificação Vascular/diagnóstico por imagem
4.
J Thorac Imaging ; 35(3): 198-203, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32032251

RESUMO

PURPOSE: The purpose of this study was to evaluate the utilization of invasive and noninvasive tests and compare cost in patients presenting with chest pain to the emergency department (ED) who underwent either triple-rule-out computed tomography angiography (TRO-CTA) or standard of care. MATERIALS AND METHODS: We performed a retrospective single-center analysis of 2156 ED patients who presented with acute chest pain with a negative initial troponin and electrocardiogram for myocardial injury. Patient cohorts matched by patient characteristics who had undergone TRO-CTA as a primary imaging test (n=1139) or standard of care without initial CTA imaging (n=1017) were included in the study. ED visits, utilization of tests, and costs during the initial episode of hospital care were compared. RESULTS: No significant differences in the diagnosis of coronary artery disease, pulmonary embolism, or aortic dissection were observed. Median ED waiting time (4.5 vs. 7.0 h, P<0.001), median total length of hospital stay (5.0 vs. 32.0 h, P<0.001), hospital admission rate (12.6% vs. 54.2%, P<0.001), and ED return rate to our hospital within 30 days (3.5% vs. 14.6%, P<0.001) were significantly lower in the TRO-CTA group. Moreover, reduced rates of additional testing and invasive coronary angiography (4.9% vs. 22.7%, P<0.001), and ultimately lower total cost per patient (11,783$ vs. 19,073$, P<0.001) were observed in the TRO-CTA group. CONCLUSIONS: TRO-CTA as an initial imaging test in ED patients presenting with acute chest pain was associated with shorter ED and hospital length of stay, fewer return visits within 30 days, and ultimately lower ED and hospitalization costs.


Assuntos
Dor no Peito/economia , Angiografia por Tomografia Computadorizada/economia , Angiografia Coronária/economia , Doença da Artéria Coronariana/complicações , Custos e Análise de Custo/métodos , Padrão de Cuidado/economia , Dor Aguda/líquido cefalorraquidiano , Dor Aguda/diagnóstico por imagem , Dor Aguda/economia , Dor Aguda/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Dor no Peito/diagnóstico por imagem , Dor no Peito/etiologia , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Angiografia Coronária/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/economia , Custos e Análise de Custo/economia , Custos e Análise de Custo/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Padrão de Cuidado/estatística & dados numéricos , Adulto Jovem
5.
Radiol Cardiothorac Imaging ; 2(3): e190137, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33778579

RESUMO

PURPOSE: To evaluate the additional value of noninvasive artificial intelligence (AI)-based CT-derived fractional flow reserve (CT FFR), derived from triple-rule-out coronary CT angiography for acute chest pain (ACP) in the emergency department (ED) setting. MATERIALS AND METHODS: AI-based CT FFR from triple-rule-out CT angiography data sets was retrospectively obtained in 159 of 271 eligible patients (102 men; mean age, 57.0 years ± 9.7 [standard deviation]) presenting to the ED with ACP. The agreement between CT FFR (≤ 0.80) and stenosis at triple-rule-out CT angiography (≥ 50%), as well as downstream cardiac diagnostic testing, was investigated. Furthermore, the predictive value of CT FFR for coronary revascularization and major adverse cardiac events (MACE) was assessed over a 1-year follow-up period. RESULTS: CT FFR and triple-rule-out CT angiography demonstrated agreement in severity of coronary artery disease (CAD) in 52% (82 of 159) of all cases. CT FFR of 0.80 and less served as a better predictor for coronary revascularization and MACE than stenosis of 50% and greater at triple-rule-out CT angiography (odds ratio, 3.4; 95% confidence interval: 1.4, 8.2 vs odds ratio, 2.2; 95% confidence interval: 0.9, 5.3) (P < .01). In the subgroup of patients with additional noninvasive cardiac testing (94 of 159), there was higher agreement as to the presence or absence of significant disease with CT FFR (55%) than with coronary triple-rule-out CT angiography (47%) (P = .23). CONCLUSION: CT FFR derived from triple-rule-out CT angiography was a better predictor for coronary revascularization and MACE and showed better agreement with additional diagnostic testing than triple-rule-out CT angiography. Therefore, CT FFR may improve the specificity in identifying patients with ACP with significant CAD in the ED setting and reduce unnecessary downstream testing.© RSNA, 2020See also the commentary by Ihdayhid and Ben Zekry in this issue.

6.
Eur J Radiol ; 119: 108657, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31521876

RESUMO

PURPOSE: This study investigated the impact of gender differences on the diagnostic performance of machine-learning based coronary CT angiography (cCTA)-derived fractional flow reserve (CT-FFRML) for the detection of lesion-specific ischemia. METHOD: Five centers enrolled 351 patients (73.5% male) with 525 vessels in the MACHINE (Machine leArning Based CT angiograpHy derIved FFR: a Multi-ceNtEr) registry. CT-FFRML and invasive FFR ≤ 0.80 were considered hemodynamically significant, whereas cCTA luminal stenosis ≥50% was considered obstructive. The diagnostic performance to assess lesion-specific ischemia in both men and women was assessed on a per-vessel basis. RESULTS: In total, 398 vessels in men and 127 vessels in women were included. Compared to invasive FFR, CT-FFRML reached a sensitivity, specificity, positive predictive value, and negative predictive value of 78% (95%CI 72-84), 79% (95%CI 73-84), 75% (95%CI 69-79), and 82% (95%CI: 76-86) in men vs. 75% (95%CI 58-88), 81 (95%CI 72-89), 61% (95%CI 50-72) and 89% (95%CI 82-94) in women, respectively. CT-FFRML showed no statistically significant difference in the area under the receiver-operating characteristic curve (AUC) in men vs. women (AUC: 0.83 [95%CI 0.79-0.87] vs. 0.83 [95%CI 0.75-0.89], p = 0.89). CT-FFRML was not superior to cCTA alone [AUC: 0.83 (95%CI: 0.75-0.89) vs. 0.74 (95%CI: 0.65-0.81), p = 0.12] in women, but showed a statistically significant improvement in men [0.83 (95%CI: 0.79-0.87) vs. 0.76 (95%CI: 0.71-0.80), p = 0.007]. CONCLUSIONS: Machine-learning based CT-FFR performs equally in men and women with superior diagnostic performance over cCTA alone for the detection of lesion-specific ischemia.


Assuntos
Angiografia por Tomografia Computadorizada/normas , Estenose Coronária/diagnóstico por imagem , Isquemia Miocárdica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Angiografia Coronária/normas , Estenose Coronária/fisiopatologia , Métodos Epidemiológicos , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Hemodinâmica/fisiologia , Humanos , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Fatores Sexuais , Tomografia Computadorizada Espiral/métodos , Tomografia Computadorizada Espiral/normas
7.
BMC Cardiovasc Disord ; 19(1): 39, 2019 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-30744612

RESUMO

BACKGROUND: The heterogeneity of risk in patients with diabetes mellitus (DM) is acknowledged in new guidelines promulgating different treatment recommendations for diabetics at low cardiac risk. We performed a retrospective longitudinal follow-up study to evaluate coronary plaque progression and its impact on cardiac events in asymptomatic diabetic patients. METHODS: Data of 197 asymptomatic patients (63.1 ± 17 years, 60% males) with DM and suspected coronary artery disease (CAD) who underwent clinically indicated dual-source cardiac computed tomography (CT) were retrospectively analyzed. Patients with DM received standard of care treatment. Patients were classified into two groups based on CT coronary artery calcium scores (CACS): A, CACS> 10; B, CACS≤10. Progression of coronary plaque burden in both groups was evaluated and compared by baseline and follow-up coronary CT angiography (CCTA) using semi-automated plaque analysis and quantification software. Follow-up data were retrospectively gathered from medical records and endpoints of cardiac events were recorded via prospective phone-calls. The impacts of plaque composition and progression on cardiac events were specifically assessed. RESULTS: Patients with CACS> 10 showed an increase in dense coronary calcium volume, while patients with CACS≤10 had a more pronounced increase in the volume of low-attenuation "lipid-rich" plaque components between CCTA acquisitions. The composite endpoint occurred in 20 patients (10.2%) after a median follow-up period of 41.8 months. Furthermore, at follow-up CCTA, the presence of CACS> 10 (adjusted odds ratio, 0.701; 95% CI, 0.612-0.836), increase of dense calcium volume (OR, 0.860 95% CI, 0.771-0.960), and lipid volume (OR, 1.013; 95% CI, 1.007-1.020) were all independent predictors of cardiac events. CONCLUSION: Asymptomatic patients with DM experienced plaque progression as well as progression to "overt or silent CAD". The relative increase in plaque volume was associated with subsequent cardiac events, and the coronary calcification seemed to be inversely related to the outcome in asymptomatic diabetic patients.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Diabetes Mellitus , Placa Aterosclerótica , Calcificação Vascular/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Doenças Assintomáticas , China/epidemiologia , Doença da Artéria Coronariana/epidemiologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Calcificação Vascular/epidemiologia
8.
Eur Radiol ; 29(9): 4783-4793, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30805703

RESUMO

OBJECTIVES: To investigate the diagnostic accuracy of a modified three-material decomposition calcium subtraction (CS) algorithm for the detection of arterial stenosis in dual-energy CT angiography (DE-CTA) of the lower extremity runoff compared to standard image reconstruction, using digital subtraction angiography (DSA) as the reference standard. METHODS: Eighty-eight patients (53 males; mean age, 65.9 ± 11 years) with suspected peripheral arterial disease (PAD) who had undergone a DE-CTA examination of the lower extremity runoff between May 2014 and May 2015 were included in this IRB-approved, HIPAA-compliant retrospective study. Standard linearly blended and CS images were reconstructed and vascular contrast-to-noise ratios (CNR) were calculated. Two independent observers assessed subjective image quality using a 5-point Likert scale. Diagnostic accuracy for ≥ 50% stenosis detection was analyzed in a subgroup of 45 patients who had undergone additional DSA. Diagnostic accuracy parameters were estimated with a random-effects logistic regression analysis and compared using generalized estimating equations. RESULTS: CS datasets showed higher CNR (15.3 ± 7.3) compared to standard reconstructions (13.5 ± 6.5, p < 0.001). Both reconstructions showed comparable qualitative image quality scores (CS, 4.64; standard, 4.57; p = 0.220). Diagnostic accuracy (sensitivity, specificity, positive and negative predictive values) for CS reconstructions was 96.5% (97.5%, 95.6%, 90.9%, 98.1) and 93.1% (98.8%, 90.4%, 82.3%, 99.1%) for standard images. CONCLUSIONS: A modified three-material decomposition CS algorithm provides increased vascular CNR, equivalent qualitative image quality, and greater diagnostic accuracy for the detection of significant arterial stenosis of the lower extremity runoff on DE-CTA compared with standard image reconstruction. KEY POINTS: • Calcified plaques may lead to overestimation of stenosis severity and false positive results, requiring additional invasive digital subtraction angiography (DSA). • A modified three-material decomposition algorithm for calcium subtraction provides greater diagnostic accuracy for the detection of significant arterial stenosis of the lower extremity runoff compared with standard image reconstruction. • The application of this algorithm in patients with heavily calcified vessels may be helpful to potentially reduce inconclusive CT angiography examinations and the need for subsequent invasive DSA.


Assuntos
Angiografia Digital/métodos , Arteriopatias Oclusivas/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Extremidade Inferior/irrigação sanguínea , Idoso , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Calcificação Vascular/diagnóstico por imagem
9.
Eur J Radiol ; 112: 136-143, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30777202

RESUMO

BACKGROUND: The aim of this study was to assess the potential of rest-stress DECT iodine quantification to discriminate between normal, ischemic, and infarcted myocardium. METHODS: Patients who underwent rest-stress DECT on a 2nd generation dual-source system and cardiac magnetic resonance (CMR) were retrospectively included from a prospective study cohort. CMR was performed to identify ischemic and infarcted myocardium and categorize patients into ischemic, infarcted, and control groups. Controls were analyzed on a per-slice and per-segment basis. Regions of interest (ROIs) were placed in ischemic and infarcted areas based on CMR. Additionally, ROIs were placed in the septal area to assess normal and remote myocardium. RESULTS: We included 42 patients: 10 ischemic, 17 infarcted, and 15 controls. Iodine concentrations showed no significant between segments in controls. Iodine concentrations for normal myocardium increased significantly from rest to stress (median 3.7 mg/mL (interquartile range 3.5-3.9) vs. 4.5 mg/mL (4.3-4.9)) (p < 0.001). Iodine concentrations in diseased myocardium were significantly lower than in normal myocardium; 1.3 mg/mL (0.9-1.8) and 0.6 mg/mL (0.4-0.8) at rest and stress in ischemic myocardium, and 0.3 mg/mL (0.3-0.5) and 0.5 mg/mL (0.5-0.7) at rest and stress in infarcted myocardium (p < 0.005 and p < 0.001). At rest only, iodine concentrations were significantly lower in infarcted vs. ischemic myocardium (p < 0.001). The optimal threshold for differentiating diseased from normal myocardium was 2.5 mg/mL and 2.1 mg/mL for rest and stress (AUC 1.00). To discriminate ischemic from infarcted myocardium, the optimal threshold was 1.0 mg/ml (AUC 0.944) at rest. CONCLUSION: DECT iodine concentration from rest-stress imaging can potentially differentiate between normal, ischemic, and infarcted myocardium.


Assuntos
Meios de Contraste/farmacocinética , Iodo/farmacocinética , Isquemia Miocárdica/diagnóstico , Idoso , Estudos de Casos e Controles , Teste de Esforço/métodos , Feminino , Coração/fisiologia , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Imagem de Perfusão do Miocárdio/métodos , Miocárdio/química , Estudos Prospectivos , Descanso , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
10.
J Thorac Imaging ; 34(1): 26-32, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30142137

RESUMO

PURPOSE: Recent advances in image quality of coronary computed tomographic angiography (cCTA) have enabled improved characterization of coronary plaques. Thus, we investigated the association between quantitative morphological plaque markers obtained by cCTA and serum lipid levels in patients with suspected or known coronary artery disease. MATERIALS AND METHODS: We retrospectively analyzed data of 119 statin-naive patients (55±14 y, 66% men) who underwent clinically indicated cCTA between January 2013 and February 2017. Patients were subdivided into a plaque and a no-plaque group. Quantitative and morphologic plaque markers, such as segment involvement score, segment stenosis score, remodeling index, napkin-ring sign, total plaque volume, calcified plaque volume, and noncalcified plaque volume (NCPV) and plaque composition, were analyzed using a semiautomated plaque software prototype. Total cholesterol, low-density lipoprotein (LDL), high-density lipoprotein, low-density lipoprotein/high-density lipoprotein ratio, and triglycerides were determine in both groups. RESULTS: Higher age (61±11 y vs. 52±14 y, P<0.0001) and a higher likelihood of male gender (77% vs. 56%, P<0.0001) were observed in the plaque group. Differences in lipid levels were neither observed for differentiation between plaque presence or absence, nor after subcategorization for plaque composition. LDL serum levels >160 mg/dL correlated with higher NCPV compared with patients with LDL between 100 and 160 mg/dL (112 vs. 27 mm, P=0.037). Other markers were comparable between the different groups. CONCLUSION: Statin-naive patients with known or suspected coronary artery disease did not show differences in lipid levels related to plaque composition by cCTA. Patients with plaques tended to be men and were significantly older. High LDL levels correlated with high NCPV.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/diagnóstico por imagem , Lipídeos/sangue , Placa Aterosclerótica/diagnóstico por imagem , Fatores Etários , Idoso , Biomarcadores/sangue , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/sangue , Estudos Retrospectivos , Fatores Sexuais , Calcificação Vascular/sangue , Calcificação Vascular/diagnóstico por imagem
11.
J Cardiovasc Comput Tomogr ; 13(6): 331-335, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30391256

RESUMO

BACKGROUND: The influence of computed tomography (CT) reconstruction algorithms on the performance of machine-learning-based CT-derived fractional flow reserve (CT-FFRML) has not been investigated. CT-FFRML values and processing time of two reconstruction algorithms were compared using an on-site workstation. METHODS: CT-FFRML was computed on 40 coronary CT angiography (CCTA) datasets that were reconstructed with both iterative reconstruction in image space (IRIS) and filtered back-projection (FBP) algorithms. CT-FFRML was computed on a per-vessel and per-segment basis as well as distal to lesions with ≥50% stenosis on CCTA. Processing times were recorded. Significant flow-limiting stenosis was defined as invasive FFR and CT-FFRML values ≤ 0.80. Pearson's correlation, Wilcoxon, and McNemar statistical testing were used for data analysis. RESULTS: Per-vessel analysis of IRIS and FBP reconstructions demonstrated significantly different CT-FFRML values (p ≤ 0.05). Correlation of CT-FFRML values between algorithms was high for the left main (r = 0.74), left anterior descending (r = 0.76), and right coronary (r = 0.70) arteries. Proximal and middle segments showed a high correlation of CT-FFRML values (r = 0.73 and r = 0.67, p ≤ 0.001, respectively), despite having significantly different averages (p ≤ 0.05). No difference in diagnostic accuracy was observed (both 81.8%, p = 1.000). Of the 40 patients, 10 had invasive FFR results. Per-lesion correlation with invasive FFR values was moderate for IRIS (r = 0.53, p = 0.117) and FBP (r = 0.49, p = 0.142). Processing time was significantly shorter using IRIS (15.9 vs. 19.8 min, p ≤ 0.05). CONCLUSION: CT reconstruction algorithms influence CT-FFRML analysis, potentially affecting patient management. Additionally, iterative reconstruction improves CT-FFRML post-processing speed.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Aprendizado de Máquina , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Fluxo de Trabalho
12.
Eur Radiol ; 29(6): 3017-3026, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30377794

RESUMO

PURPOSE: To evaluate the feasibility of fractional flow reserve (cFFR) derivation from coronary CT angiography (CCTA) in patients with myocardial bridging (MB), its relationship with MB anatomical features, and clinical relevance. METHODS: This retrospective study included 120 patients with MB of the left anterior descending artery (LAD) and 41 controls. MB location, length, depth, muscle index, instance, and stenosis rate were measured. cFFR values were compared between superficial MB (≤ 2 mm), deep MB (> 2 mm), and control groups. Factors associated with abnormal cFFR values (≤ 0.80) were analyzed. RESULTS: MB patients demonstrated lower cFFR values in MB and distal segments than controls (all p < 0.05). A significant cFFR difference was only found in the MB segment during systole between superficial (0.94, 0.90-0.96) and deep MB (0.91, 0.83-0.95) (p = 0.018). Abnormal cFFR values were found in 69 (57.5%) MB patients (29 [49.2%] superficial vs. 40 [65.6%] deep; p = 0.069). MB length (OR = 1.06, 95% CI 1.03-1.10; p = 0.001) and systolic stenosis (OR = 1.04, 95% CI 1.01-1.07; p = 0.021) were the main predictors for abnormal cFFR, with an area under the curve of 0.774 (95% CI 0.689-0.858; p < 0.001). MB patients with abnormal cFFR reported more typical angina (18.8% vs 3.9%, p = 0.023) than patients with normal values. CONCLUSION: MB patients showed lower cFFR values than controls. Abnormal cFFR values have a positive association with symptoms of typical angina. MB length and systolic stenosis demonstrate moderate predictive value for an abnormal cFFR value. KEY POINTS: • MB patients showed lower cFFR values than controls. • Abnormal cFFR values have a positive association with typical angina symptoms. • MB length and systolic stenosis demonstrate moderate predictive value for an abnormal cFFR value .


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Ponte Miocárdica/diagnóstico , Adulto , Idoso , Vasos Coronários/fisiopatologia , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Ponte Miocárdica/fisiopatologia , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença
13.
Radiol Clin North Am ; 56(4): 521-534, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29936945

RESUMO

Dual energy computed tomography is becoming increasingly widespread in clinical practice. It can expand on the traditional density-based data achievable with single energy computed tomography by adding novel applications to help reach a more accurate diagnosis. The implementation of this technology in cardiothoracic vascular imaging allows for improved image contrast, metal artifact reduction, generation of virtual unenhanced images, virtual calcium subtraction techniques, cardiac and pulmonary perfusion evaluation, and plaque characterization. The improved diagnostic performance afforded by dual energy computed tomography is not associated with an increased radiation dose. This review provides an overview of dual energy computed tomography cardiothoracic vascular applications.


Assuntos
Cardiopatias/diagnóstico por imagem , Pneumopatias/diagnóstico por imagem , Artefatos , Vasos Coronários/diagnóstico por imagem , Coração/diagnóstico por imagem , Humanos , Pulmão/irrigação sanguínea , Pulmão/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X
15.
Eur Radiol Exp ; 2(1): 6, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29708212

RESUMO

BACKGROUND: Assessing the extent of ischemic and reperfusion-associated myocardial injuries remains challenging with current magnetic resonance imaging (MRI) techniques. Our aim was to develop a tissue characterization mapping (TCM) technique by combining late gadolinium enhancement (LGE) with our novel percent edema mapping (PEM) approach to enable the classification of tissue represented by MRI voxels as healthy, myocardial edema (ME), necrosis, myocardial hemorrhage (MH), or scar. METHODS: Six dogs underwent closed-chest myocardial infarct (MI) generation. Serial MRI scans were performed post-MI on days 3, 4, 6, 14, and 56, including T2 mapping and LGE. Dogs were sacrificed on day 4 (n = 4, acute MI) or day 56 (n = 2, chronic MI). TCMs were generated based on a voxel classification algorithm taking into account signal intensity from LGE and T2-based estimation of ME. TCM-based MI and MH were validated with post mortem triphenyl tetrazolium chloride (TTC) staining. Pearson's correlation and Bland-Altman analyses were performed. RESULTS: The MI, ME, and MH measured by TCM were 13.4% [25th-75th percentile 1.6-28.8], 28.1% [2.1-37.5] and 4.3% [1.0-11.3], respectively. TCM measured higher MH and MI compared to TTC (p = 0.0033 and p = 0.0007, respectively). MH size was linearly correlated with MI size by both MRI (r = 0.9528, p < 0.0001) and TTC (r = 0.9625, p < 0.0001). MH quantification demonstrated good agreement between TCM and TTC (r = 0.8766, p < 0.0001, 2.4% overestimation by TCM). A similar correlation was observed for MI size (r = 0.9429, p < 0.0001, 6.1% overestimation by TCM). CONCLUSIONS: Preliminary results suggest that the TCM method is feasible for the in vivo localization and quantification of various MI-related tissue components.

16.
Eur J Radiol ; 101: 111-117, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29571783

RESUMO

PURPOSE: To investigate the effect of an iterative beam-hardening correction algorithm (iBHC) on artifact reduction and image quality in coronary CT angiography (cCTA) with low tube voltage. MATERIAL AND METHODS: Thirty-six patients (17 male, mean age, 57.3 ±â€¯14.5 years) were prospectively enrolled in this IRB-approved study and underwent 70-kV cCTA using a third-generation dual-source CT scanner. Images were reconstructed using a standard algorithm (Bv36) both with and without the iBHC technique. Several region-of-interest (ROI) measurements were performed in the inferior wall of the left ventricle (LV), an area prone to beam-hardening, as well as other myocardial regions. Coronary contrast-to-noise (CNR) and signal-to-noise ratios (SNR) were calculated. Two radiologists assessed subjective image quality. RESULTS: The iBHC algorithm generally increased myocardial attenuation in all ROIs (P < 0.566); however, the increase was significantly more distinct in beam-hardening prone areas such as the inferior LV (increase, +13.9 HU, +18.6%, P < 0.001), compared to the remaining myocardium (increase, +4.4 HU, +4.5%, P < 0.003). While no significant difference was found for image noise (P < 0.092), greater CNR and SNR values for the left main coronary artery (increase, +20.7% and +17.3%, respectively) were found using the iBHC algorithm (both with P < 0.001). Subjective image quality was comparable between both image series (P = 0.217). CONCLUSION: The iBHC post-processing algorithm leads to significantly reduced beam-hardening while providing improved objective and equivalent subjective image quality in 70-kV cCTA.


Assuntos
Artefatos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
17.
Eur J Radiol ; 101: 92-96, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29571808

RESUMO

PURPOSE: To compare the effect of dual-source dual-energy CT versus single-energy CT on DNA double-strand breaks (DSBs) in blood lymphocytes at CT pulmonary angiography (CTPA). METHODS AND MATERIALS: Sixty-two patients underwent either dual-energy CTPA (Group 1: n = 21, 80/Sn140 kVp, 89/38 mAs; Group 2: n = 20, 100/Sn140 kVp, 89/76 mAs) or single-energy CTPA (Group 3: n = 21, 120 kVp, 110 mAs). Blood samples were obtained before and 5 min after CTPA. DSBs were assessed with fluorescence microscopy and Kruskal-Walls tests were used to compare DSBs levels among groups. Volume CT dose index (CTDIvol), dose length product (DLP) and organ radiation dose were compared using ANOVA. RESULTS: There were increased excess DSB foci per lymphocyte 5 min after CTPA examinations in three groups (Group 1: P = .001; Group 2: P = .001; Group 3: P = .006). There were no differences among groups regarding excess DSB foci/cell and percentage of excess DSBs (Group 1, 23%; Group 2, 24%; Group 3, 20%; P = .932). CTDIvol, DLP and organ radiation dose in Group 1 were the lowest among the groups (all P < .001). CONCLUSION: DSB is increased following dual-source and single-source CTPA, while dual-source dual-energy CT protocols do not increase the estimated radiation dose and also do not result in a higher incidence of DNA DSBs in patients undergoing CTPA.


Assuntos
Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Quebras de DNA de Cadeia Dupla/efeitos da radiação , Pulmão/diagnóstico por imagem , Doses de Radiação , Exposição à Radiação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/estatística & dados numéricos , Feminino , Humanos , Pulmão/irrigação sanguínea , Linfócitos/efeitos da radiação , Masculino , Pessoa de Meia-Idade
18.
Eur Radiol ; 28(7): 3097-3104, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29404770

RESUMO

OBJECTIVES: To investigate diagnostic accuracy and radiation dose of high-pitch CT coronary artery calcium scoring (CACS) with tin filtration (Sn100kVp) versus standard 120kVp high-pitch acquisition. METHODS: 78 patients (58% male, 61.5±9.1 years) were prospectively enrolled. Subjects underwent clinical 120kVp high-pitch CACS using third-generation dual-source CT followed by additional high-pitch Sn100kVp acquisition. Agatston scores, calcium volume scores, Agatston score categories, percentile-based risk categorization and radiation metrics were compared. RESULTS: 61/78 patients showed coronary calcifications. Median Agatston scores were 34.9 [0.7-197.1] and 41.7 [0.7-207.2] and calcium volume scores were 34.1 [0.7-218.0] for Sn100kVp and 35.7 [1.1-221.0] for 120kVp acquisitions, respectively (both p<0.0001). Bland-Altman analysis revealed underestimated Agatston scores and calcium volume scores with Sn100kVp versus 120kVp acquisitions (mean difference: 16.4 and 11.5). However, Agatston score categories and percentile-based risk categories showed excellent agreement (ĸ=0.98 and ĸ=0.99). Image noise was 25.8±4.4HU and 16.6±2.9HU in Sn100kVp and 120kVp scans, respectively (p<0.0001). Dose-length-product was 9.9±4.8mGy*cm and 40.9±14.4mGy*cm with Sn100kVp and 120kVp scans, respectively (p<0.0001). This resulted in significant effective radiation dose reduction (0.13±0.07mSv vs. 0.57±0.2mSv, p<0.0001) for Sn100kVp acquisitions. CONCLUSION: CACS using high-pitch low-voltage tin-filtered acquisitions demonstrates excellent agreement in Agatston score and percentile-based cardiac risk categorization with standard 120kVp high-pitch acquisitions. Furthermore, radiation dose was significantly reduced by 78% while maintaining accurate risk prediction. KEY POINTS: • Coronary artery calcium scoring with tin filtration reduces radiation dose by 78%. • There is excellent correlation between high-pitch Sn100kVp and standard 120kVp acquisitions. • Excellent agreement regarding Agatston score categories and percentile-based risk categorization was achieved. • No cardiac risk reclassifications were observed using Sn100kVp coronary artery calcium scoring.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Cálcio , Feminino , Filtração/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Medição de Risco/métodos , Estanho
19.
Eur Radiol ; 28(5): 2134-2142, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29181587

RESUMO

OBJECTIVES: To compare the diagnostic accuracy between low-kilovolt peak (kVp) (≤ 100) and high-kVp (> 100) third-generation dual-source coronary CT angiography (CCTA) using a kVp-tailored contrast media injection protocol. METHODS: One hundred twenty patients (mean age = 62.6 years, BMI = 29.0 kg/m2) who underwent catheter angiography and CCTA with automated kVp selection were separated into two cohorts (each n = 60, mean kVp = 84 and 117). Contrast media dose was tailored to the kVp level: 70 = 40 ml, 80 = 50 ml, 90 = 60 ml, 100 = 70 ml, 110 = 80 ml, and 120 = 90 ml. Contrast-to-noise ratio (CNR) was measured. Two observers evaluated image quality and the presence of significant coronary stenosis (> 50% luminal narrowing). RESULTS: Diagnostic accuracy (sensitivity/specificity) with ≤ 100 vs. > 100 kVp CCTA was comparable: per patient = 93.9/92.6% vs. 90.9/92.6%, per vessel = 91.5/97.8% vs. 94.0/96.8%, and per segment = 90.0/96.7% vs. 90.7/95.2% (all P > 0.64). CNR was similar (P > 0.18) in the low-kVp vs. high-kVp group (12.0 vs. 11.1), as ws subjective image quality (P = 0.38). Contrast media requirements were reduced by 38.1% in the low- vs. high-kVp cohort (53.6 vs. 86.6 ml, P < 0.001) and radiation dose by 59.6% (4.3 vs. 10.6 mSv, P < 0.001). CONCLUSIONS: Automated tube voltage selection with a tailored contrast media injection protocol allows CCTA to be performed at ≤ 100 kVp with substantial dose reductions and equivalent diagnostic accuracy for coronary stenosis detection compared to acquisitions at > 100 kVp. KEY POINTS: • Low-kVp coronary CT angiography (CCTA) enables reduced contrast and radiation dose. • Diagnostic accuracy is comparable between ≤ 100 and > 100 kVp CCTA. • Image quality is similar for low- and high-kVp CCTA. • Low-kVp image acquisition is facilitated by automated tube voltage selection. • Tailoring contrast injection protocols to the automatically selected kVp-level is feasible.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Idoso , Feminino , Seguimentos , Humanos , Injeções Intra-Arteriais , Masculino , Pessoa de Meia-Idade , Curva ROC , Doses de Radiação
20.
Am J Cardiol ; 120(12): 2121-2127, 2017 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-29102036

RESUMO

This study investigated the performance of coronary computed tomography angiography (cCTA) with cCTA-derived fractional flow reserve (CT-FFR) compared with invasive coronary angiography (ICA) with fractional flow reserve (FFR) for therapeutic decision making in patients with suspected coronary artery disease (CAD). Seventy-four patients (62 ± 11 years, 62% men) with at least 1 coronary stenosis of ≥50% on clinically indicated dual-source cCTA, who had subsequently undergone ICA with FFR measurement, were retrospectively evaluated. CT-FFR values were computed using an on-site machine-learning algorithm to assess the functional significance of CAD. The therapeutic strategy (optimal medical therapy alone vs revascularization) and the appropriate revascularization procedure (percutaneous coronary intervention vs coronary artery bypass grafting) were selected using cCTA-CT-FFR. Thirty-six patients (49%) had a functionally significant CAD based on ICA-FFR. cCTA-CT-FFR correctly identified a functionally significant CAD and the need of revascularization in 35 of 36 patients (97%). When revascularization was deemed indicated, the same revascularization procedure (32 percutaneous coronary interventions and 3 coronary artery bypass grafting) was chosen in 35 of 35 patients (100%). Overall, identical management strategies were selected in 73 of the 74 patients (99%). cCTA-CT-FFR shows excellent performance to identify patients with and without the need for revascularization and to select the appropriate revascularization strategy. cCTA-CT-FFR as a noninvasive "one-stop shop" has the potential to change diagnostic workflows and to directly inform therapeutic decision making in patients with suspected CAD.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Tomada de Decisões , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Estenose Coronária/fisiopatologia , Estenose Coronária/cirurgia , Vasos Coronários/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...